• Home
  • Cooling Unit Sizing Table 3200VSi-ECX | CellarPro

3200VSi-ECX: Sizing Table - Wine Cellars 400-800 cubic ft

55°F Cooling Capacity

Cooling Unit Output

Low Fan Speed
2487 BTUH
Decibels 54

Medium Fan Speed
2876 BTUH
Decibels 58

High Fan Speed
3040 BTUH
Decibels 66

Cellar Size

Ambient
Temperature
Thermal Load (BTUH)
R12R19R30

400

Cubic Feet

70°F181016761596
75°F192117441636
80°F203318111676
85°F214618791717
90°F225619461758
95°F236920151800

500

Cubic Feet

70°F211119581867
75°F223820351913
80°F236621121958
85°F249421902006
90°F262222672052
95°F275023452100

600

Cubic Feet

70°F235921922092
75°F250022782143
80°F263923622194
85°F277924462244
90°F292025312296
95°F304026162347

700

Cubic Feet

70°F263024502340
75°F278225422395
80°F298426342452
85°F27252506
90°F28182562
95°F29102617

800

Cubic Feet

70°F290227112596
75°F304028072653
80°F29042712
85°F30012771
90°F2828
95°F2887

60°F Cooling Capacity

Cooling Unit Output

Low Fan Speed
2663 BTUH
Decibels 54

Medium Fan Speed
3084 BTUH
Decibels 58

High Fan Speed
3258 BTUH
Decibels 66

Cellar Size

Ambient
Temperature
Thermal Load (BTUH)
R12R19R30

400

Cubic Feet

70°F159314751404
75°F169015351440
80°F178915941475
85°F188816541511
90°F198517121547
95°F208517731584

500

Cubic Feet

70°F185817231643
75°F196917911683
80°F208218591723
85°F219619271765
90°F230719951806
95°F269323022065

600

Cubic Feet

70°F231421562059
75°F244822372108
80°F258223182158
85°F244621521975
90°F257022272020
95°F269323022065

700

Cubic Feet

70°F231421562059
75°F244822372108
80°F258223182158
85°F271623982205
90°F285024802255
95°F298425612303

800

Cubic Feet

70°F255423862284
75°F269424702335
80°F283425562387
85°F297626412438
90°F311627253489
95°F325828112541

The tables are shaded to show how the 3200VS cooling unit will work at maintaining 55°F (upper table) and 60°F (lower table) inside the wine cellar, using various fan speeds and thermal loads. The thermal loads are derived from assumptions about the size of the cellar, the R-value in the six cellar surfaces (ie walls, floor and ceiling), and the ambient temperature outside the cellar.

CellarPro 3200 wine cooling units are designed to maintain optimal wine storage temperatures in wine cellars up to 800 cubic feet with adequate insulation, and can be operated with the condenser exposed to conditions up to 115°F. For more information, click on our 3200VS performance and test data.

The thermal loads above are calculated based on the R-Values shown for all walls and ceiling, and a concrete floor. Lower R-Values in the cellar (eg from glass doors) will increase the thermal load on the wine cellar and will require the cooling unit to operate at higher fan speeds. Warmer climates require higher insulation to enable the cooling unit to operate at lower fan speeds. To be certain that the thermal load won't exceed the capacity of the cooling unit, email your wine cellar specifications to us and we'll be glad to assist you.

Cells shaded blue indicate loads that exceed the capacity of the cooling units shown in this table.